Plasmid Isolation from Bacteria: Difference between revisions
New Template:Method Page |
|||
| (4 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
{{Pagetop}} | {{Pagetop}} | ||
== Purpose == | == Purpose == | ||
This protocol is used to isolate a desired plasmid from a bacteria containing the plasmid. | |||
== Materials Needed == | == Materials Needed == | ||
-1.5 mL Microfuge tubes | |||
-Microcolumns with 2 mL collection tubes | |||
-distilled water | |||
-Cell Lysis Buffer | |||
-Neutralization Solution (NSC) | |||
-Endotoxin Removal Wash | |||
-Column Wash Solution | |||
-Micropipette | |||
-Centrifuge | |||
-Bacteria with plasmid DNA | |||
-Broth for bacteria to grow in | |||
== Protocol == | == Protocol == | ||
-Grow the bacteria to saturation in an appropriate broth media overnight | |||
-Centrifuge the bacterial sample in a microfuge tube at 15,000 rpm for 30 seconds | |||
-Dispose of the supernatant and resuspend the pellet in 600 microliters of distilled water | |||
-Add 100 microliters of Cell Lysis Buffer and mix by shaking | |||
-Add 350 microliters of NSC and mix by shaking | |||
-Centrifuge for 3 minutes at 15,000 rpm | |||
-Transfer the supernatant to a microcolumn and centrifuge for 30 seconds at 15,000 rpm | |||
-Discard the flow through and wash the column with 200 microliters of Endotoxin Removal Wash, centrifuge for 30 seconds at 15,000 rpm | |||
-Discard the flow through and wash the column with 400 microliters of Column Wash Solution, centrifuge for 30 seconds at 15,000 rpm | |||
-Discard the flow through and place the column in a fresh microfuge tube | |||
-Wash the column with 30-50 microliters of distilled water, depending on how much bacteria was used, let it sit for one minute, then centrifuge for 30 seconds at 15,000 rpm | |||
-The plasmid is in the water in the microfuge tube | |||
== Notes == | == Notes == | ||
Latest revision as of 20:05, 20 July 2015
You can help OMP wiki by editing the content of this page. For information about becoming a registered user and obtaining editing privileges, see Help:Accounts.
Purpose
This protocol is used to isolate a desired plasmid from a bacteria containing the plasmid.
Materials Needed
-1.5 mL Microfuge tubes
-Microcolumns with 2 mL collection tubes
-distilled water
-Cell Lysis Buffer
-Neutralization Solution (NSC)
-Endotoxin Removal Wash
-Column Wash Solution
-Micropipette
-Centrifuge
-Bacteria with plasmid DNA
-Broth for bacteria to grow in
Protocol
-Grow the bacteria to saturation in an appropriate broth media overnight
-Centrifuge the bacterial sample in a microfuge tube at 15,000 rpm for 30 seconds
-Dispose of the supernatant and resuspend the pellet in 600 microliters of distilled water
-Add 100 microliters of Cell Lysis Buffer and mix by shaking
-Add 350 microliters of NSC and mix by shaking
-Centrifuge for 3 minutes at 15,000 rpm
-Transfer the supernatant to a microcolumn and centrifuge for 30 seconds at 15,000 rpm
-Discard the flow through and wash the column with 200 microliters of Endotoxin Removal Wash, centrifuge for 30 seconds at 15,000 rpm
-Discard the flow through and wash the column with 400 microliters of Column Wash Solution, centrifuge for 30 seconds at 15,000 rpm
-Discard the flow through and place the column in a fresh microfuge tube
-Wash the column with 30-50 microliters of distilled water, depending on how much bacteria was used, let it sit for one minute, then centrifuge for 30 seconds at 15,000 rpm
-The plasmid is in the water in the microfuge tube
Notes
Papers where this or a similar method has been used
<PMIDsummary />
Related Ontology Terms
References
See Help:References for how to manage references in OMPwiki.